ENBA EN 33331
- ExxonMobil Chemical
You`ll need an account to perform this action. Don't worry. It's free!
Sign UpExxonMobil EN 33331 is a very high flow, 32.5% nBA copolymer suitable for use in hot melt adhesives and sealants.
You`ll need an account to add a review. Don't worry. It's free!
Sign UpYou`ll need to place an order to add a review. Don't worry. It's easy!
Documents
Product Details
- Manufacturer
ExxonMobil Chemical
- Plastic Generic Family
Polyethylene (PE)
Properties
Physical Properties
Title | Value | Unit | Method | Additional Information | Property Notes |
---|---|---|---|---|---|
Density | 0.923 | gm/cm³ | ASTM D1505 | - | - |
Melt Flow Index | 330 | gm/10 min | ASTM D1238 | (190°C / 2.16 Kg) | - |
Durometer Hardness | 54 | ASTM D2240 | (SHORE A , 15 SEC) | - |
Mechanical Properties
Title | Value | Unit | Method | Additional Information | Property Notes |
---|---|---|---|---|---|
Tensile strength at Break | 1.3 | MPa | ASTM D638 | - | - |
Elongation @ Break | 100 | % | ASTM D638 | - | - |
Flexural Modulus | 7.1 | MPa | ASTM D790 | (1% Secant) | - |
Thermal properties
Title | Value | Unit | Method | Additional Information | Property Notes |
---|---|---|---|---|---|
Peak Melting Temperature | 62 | °C | EXXONMOBIL Method | - | - |
Legal Statement:
This product is not intended for use in medical applications and should not be used in any such applications. Contact your ExxonMobil Chemical Customer Service Representative for potential food contact application compliance (e.g. FDA, EU, HPFB).
Notes:
Typical properties: these are not to be construed as specifications.
Product may not be available in one or more countries in the identified Availability regions. Please contact your Sales Representative for complete Country Availability.
Melt Index reported is an estimate based on ExxonMobil's correlation from melt flow rate data measured at other standard conditions.
Plastic Generic Family | Polyethylene (PE) |
---|---|
Description | Legal Statement: This product is not intended for use in medical applications and should not be used in any such applications. Contact your ExxonMobil Chemical Customer Service Representative for potential food contact application compliance (e.g. FDA, EU, HPFB).
Notes: Typical properties: these are not to be construed as specifications. Product may not be available in one or more countries in the identified Availability regions. Please contact your Sales Representative for complete Country Availability. Melt Index reported is an estimate based on ExxonMobil's correlation from melt flow rate data measured at other standard conditions.
|
- Product Review